Gwinnett Index

Duluth UDC § 1014

Standard Specifications

Governing jurisdiction
Duluth

Land inside these city limits is governed by Duluth's own code and boards. A "Duluth, GA" mailing address is not proof of being inside them — most such addresses fall in unincorporated Gwinnett.

Boundary: US Census TIGERweb (Incorporated Places, ACS 2025 vintage), vintage 2025.

Article
10 — Erosion Control and Stormwater Management
Pages in source
279
Adopted
2025-09-08
Amended through
2026-07-13
Source
Adopted PDF

Text

1014.01. Allowable Pipe Materials 1. Reinforced concrete pipe (RCP) is required to be used for stormwater conveyance within the right-of-way or in systems that are intended for dedication to the City of Duluth. 2. RCP is required when pipe slopes are less than 1%. 3. RCP is required when conveying waters of the state. 4. RCP is required for detention ponds/ vault outlet control structures and outlet pipes. 5. Other pipe materials may be used to convey onsite stormwater runoff on private development projects in accordance with the manufacturer’s specifications and Professional Engineer’s design. 6. RCP shall be a minimum of Class III, and shall be provided in joint lengths not more than 8 feet each. All joints shall be bell and spigot or tongue and groove type, with a rubber gasket conforming to ASTM C-443. Pipe shall be manufactured in accordance with AASHTO M-170 and/or ASTM C-76. Class of pipe and wall thickness shall be in accordance with 1030-D, Georgia DOT specification, Table No.1. 7. All stormwater management pipe systems must use watertight joints. 8. The City may approve an alternative pipe material.